Borg BL5401DDAMGPROECP Mechanical Digital Lock - DDA Compliant Lever - Marine Grade Pro - Easicode Pro - Black
At A Glance
The Borg BL5401DDAMGPROECP is a medium to heavy duty fully mechanical digital lever lock that brings three specifications together in one unit: Marine Grade Pro construction, Easicode Pro on-door code change, and a DDA compliant AS1428.1-2009 flat bar lever. The flat bar lever needs far less grip force than a round bar lever, which is why it is specified for disability access doors, accessible toilet facilities, and BCA-compliant commercial and institutional work. There are no batteries, no wiring and nothing to charge.
316 stainless steel internal components under the MG Pro 2 black marine coating, salt spray tested to 1,000 hours - this is the BL5401 to specify on coastal, beachside and marine sites where the satin stainless BL5401SSDDAECP would be out of its depth. Easicode Pro (ECP) changes the code on the door in about 10 seconds; the lock is cycle tested to 100,000 operations and fits doors 35mm to 54mm thick on the supplied fixings, and the inside DDA lever is always free to turn for exit. It is not fire tested: for a fire door, the On The Bench BL5401SSDDA is the fire tested DDA lock.
Usually ships same day if ordered before 11am AEST (excludes weekends and Queensland public holidays).
The BL5401DDAMGPROECP has not been fire tested, so it is not for fire door assemblies. The fire tested DDA lever lock is the On The Bench BL5401SSDDA - tested up to 4 hours (depending on the type of doorset) on fire door assemblies in accordance with AS 1905.1-2005, Part 1: Fire Resistant Doorsets - and the round bar BL5001 carries the same testing. For a fire door, choose one of those, or browse our fire door rated lock range.
The flat bar lever complies with BCA AS1428.1-2009 (Design for Access and Mobility). It needs less grip force and wrist torque than a round bar or knob lever, so it suits users with limited hand strength or dexterity - disability access doors, accessible toilet facilities, NDIS and SDA housing, and BCA-compliant commercial applications. Lever compliance relates to the handle design only; it does not imply full building access compliance for the installation, and the keypad itself still needs finger pressure. See our DDA smart locks for NDIS and disability housing guide, the DDA section of Buyer's Guide Chapter 09 and the AS1428 coverage in Chapter 11.
316 stainless steel internal components and a stainless steel coding chamber under the MG Pro 2 black marine external coating, salt spray tested to 1,000 continuous hours - a laboratory cabinet result (the finish held up that long in continuous salt fog), not a promise of service life on the coast, which is why the maintenance routine below matters. Suitable for coastal, beachside and marine environments where the satin stainless BL5401SSDDAECP is not. What MG Pro actually means on a Borg lock is decoded in MG Pro and ECP Explained, and the three-brand corrosion comparison is in Lockwood vs Borg vs Carbine.
Borg warrants the corrosion resistance of this Marine Grade Pro unit for 12 months from date of sale under specified conditions - the routine in the maintenance notes keeps those conditions met; see the warranty details.
With Easicode Pro (ECP) the lock stays on the door - Borg puts the change at about 10 seconds. With the door open, enter the current code, put the change key over the code change button at the top of the keypad, turn it 90 degrees clockwise and hold it in, press C, then enter the new code twice. Release the key, turn it back and remove it, then press C or turn the lever to set the new code - and test it five times before the door closes. The change key is in the box (a spare is the BL5000ECPCK), and so is the code change deactivation plug, which stops anyone re-coding the keypad on the door once your code is set. Step by step in how the Borg on-door change works and page 4 of the ECP Instruction Segments (PDF). Never force the change key - here is why.
Enter the code, turn the lever and press F: the outside lever stays free turning and withdraws the latch, so the door opens without a code - handy for business hours in an amenities block or a move-in day. To lock it again, turn the lever and press C; you will hear a click as the coding chamber resets. It is not a holdback - the latch still engages when the door closes. If you never want the function, the free passage deactivation plug in the box fits into the F slot on the back of the keypad and switches it off until the keypad is taken off the door. Passage mode explained.
The inside flat bar lever is always free to turn, so no code is ever needed to open the door from inside - the behaviour exit paths expect, and the same low-force action as the outside lever. If you need a code on both faces instead, the back-to-back BL5771MGPROECP does that with a key override both sides - but a back-to-back lock needs a code or key to get out, so it is not for fire doors, emergency exit or fire egress doors. Exit path logic is unpacked in our commercial guide.
The BL5401DDAMGPROECP is entirely mechanical. No power source, no wiring, no battery compartment and no battery maintenance at any point in the lock's service life - a real advantage on disability access doors in healthcare and institutional settings where power reliability must not be a factor. See why mechanical digital locks are chosen for critical access points.
Accessible toilets, amenities, offices, healthcare and institutional doors with regular daily traffic on coastal sites. Borg cycle tests the series to 100,000 operations. See our commercial mechanical digital lock guide.
For a genuinely heavy duty, high traffic DDA door consider the Carbine CDL7100SC (rear DDA lever, C7 salt spray, heavy duty body); for other high traffic doors the Lockwood 3572DX or Borg BL7701 - our high traffic guide explains what separates them.
The BL5401DDAMGPROECP, like every Borg mechanical digital lock, holds one active PIN code at a time - everyone shares the same code, and there is no audit trail. That is a characteristic of the mechanical coding chamber, not a fault. If you need individual user codes or access records, a smart lock is the right tool instead - our honest limitations rundown covers the trade-off.
Key Features
- DDA compliant flat bar lever - AS1428.1-2009; suitable for disability access, accessible toilet facilities and BCA-compliant applications. See our DDA chapter.
- Easicode Pro (ECP) on-door code change with the supplied change key - about 10 seconds, no lock removal; code change deactivation plug included.
- Over 1,000 any-order code combinations - the digits open the lock in any order. Any-order codes explained.
- Not fire tested - not for fire door assemblies; the BL5401SSDDA is the fire tested DDA lock.
- Fully mechanical - no batteries, no wiring, no electronics anywhere in the lock.
- Black MG Pro 2 marine external grade coating with 316 stainless steel internal components; 1,000 hour salt spray tested; corrosion resistance warranted 12 months.
- Clutching outside lever - free turning until the correct code is entered, so force on the lever cannot be transferred to the latch; inside DDA lever always free for exit.
- Optional free passage function (F button) - the included deactivation plug switches it off until the keypad comes off the door.
- 60mm anti-thrust stainless steel tubular latch, 12mm bolt projection; 70mm backset latch available separately - BLL500070 or black MG Pro BLSMGPRO570.
- 8mm square spindle - compatible with most leading tubular latch and lockcase brands; Lockwood 3572 and 3582 adaptor kits available.
- Door thickness 35mm to 54mm on the supplied fixings.
- Cycle tested to 100,000 operations - medium to heavy duty.
- Reversible on site for left or right hand doors with the supplied hex wrench.
Access Methods
This is a single-sided mechanical digital lock with one way in - the outside keypad - and an inside DDA lever that is always free for exit. There is no key override, app, fob or card: that is not what this category is. For a Borg flat bar lever lock with a key override, see the BL5701.
What's in the Box
- Borg BL5401DDAMGPROECP outside keypad and DDA flat bar lever assembly (black MG Pro 2)
- Inside DDA flat bar lever handle assembly (black MG Pro 2)
- 60mm anti-thrust stainless steel tubular latch (12mm bolt projection)
- Strike plate and box keep
- Spindles - 80mm and 90mm supplied (use the longest that fits)
- M4 stainless steel fixing screws - 40mm, 50mm and 60mm options
- 4 x 16mm screws
- Easicode Pro code change key
- Code change deactivation plug (optional use)
- Free passage deactivation plug (optional use)
- Hex wrench (Allen key) for handing changes
- Handle screw rubber grommet
- Installation instructions
Suitable Uses
- Disability access doors, accessible toilet facilities and amenity rooms requiring BCA AS1428.1 compliant lever hardware in commercial, strata, institutional and healthcare buildings
- NDIS SDA (Specialist Disability Accommodation) properties requiring BCA-compliant accessible hardware; see our DDA range guide for NDIS
- Sites where codes change often - staff turnover, cleaning contractors, shared facilities - and the on-door Easicode Pro change avoids a locksmith visit each time; see changing codes
- Coastal, beachside, marine and poolside accessible doors and gates - see External Gate - Exposed to Rain and our guide to where MG Pro is needed
- Not for fire door assemblies - the BL5401DDAMGPROECP is not fire tested; the BL5401SSDDA is the fire tested DDA lever lock
Available Finish Options
Black - Marine Grade Pro 2
(This Product)
BL5401DDAMGPROECP
Finish selection does not affect functionality, compliance, or performance. This Marine Grade Pro model is made in MG Pro 2 black only - a different construction grade, not just a colour change. The satin stainless Easicode Pro version is the BL5401SSDDAECP, and the fire tested On The Bench version is the BL5401SSDDA.
Borg BL5401 DDA Series - Product Family
Every BL5401 DDA model uses the same AS1428.1-2009 flat bar lever and is fully mechanical. The columns that decide the choice: the code change method, the weather grade and fire testing - only the On The Bench BL5401SSDDA is fire tested. The grade and code change naming is decoded in MG Pro and ECP Explained.
Keypad-only models are replacement outside units - they need a host lock's latch and inside handle. Same lock body with a round bar lever: the fire tested BL5001 (4 finishes) and the Easicode Pro BL5001MGPROECP. Flat bar lever with a key override: the BL5701.
Accessories and Spare Parts - BL5400 and BL5000 Series
The BL5401 sits on Borg's 5000 series platform, so its spare keypads, latches, plates and kits are all catalogued items - a damaged or worn keypad is a part swap, not a whole new lock. It is a big part of why this range outlasts hardware store imitations. One honest note on spare keypads: the catalogued DDA spare keypads are standard-grade satin stainless units - Borg does not list a black Marine Grade Pro DDA keypad as a separate spare. For a keypad replacement on a coastal install, contact us first.
The full 5000 series accessories flyer, including the BL5001002K kit for Lockwood 002 deadlocks, is in PDF Downloads below. Unsure which part suits your unit? Contact us before you order - it is quicker than a return.
Full Specifications
Dimensions
Figures from the Borg BL5400 series engineering drawings, shown full size in the Dimensions tab. Verify against current Borg documentation before specifying for constrained installations.
Frequently Asked Questions
The BL5401 uses a flat bar lever compliant with BCA AS1428.1-2009 (Design for Access and Mobility). It needs significantly less grip force and torque than a round bar lever, which makes it usable for people with limited hand strength, arthritis or reduced dexterity, and it is the correct lever type wherever BCA accessibility compliance is required of the locking hardware. Lever compliance covers the handle design only; full building access compliance is a certifier's call. See the DDA section of Chapter 09 and AS1428 in Chapter 11.
With the door open, enter the current code. Put the change key over the code change button at the top of the keypad, turn it 90 degrees clockwise and hold it in. Press C to clear, enter the new code, then enter it again to confirm. Release the key, turn it back and remove it, then press C or turn the lever to set the new code - and test it at least five times before closing the door. The code is any-order: if it is 1234, then 4321 also opens the lock. Full walkthrough with photos in our ECP code change steps and page 4 of the ECP Instruction Segments (PDF).
No. The BL5401DDAMGPROECP has not been fire tested, so it is not for fire doors. The fire tested DDA lever lock is the On The Bench BL5401SSDDA (AS 1905.1-2005, up to 4 hours depending on the type of doorset), and the round bar BL5001 carries the same testing. Browse our fire door rated locks and read the fire door certification guide.
By location. Anywhere with salt in the air - coastal, beachside, marina, poolside - needs this Marine Grade Pro model: 316 stainless steel internals under the MG Pro 2 coating, salt spray tested to 1,000 hours. Internal doors and sheltered external doors inland are well served by the satin stainless BL5401SSDDAECP, the same lever and Easicode Pro chamber at a lower price. Neither is fire tested - for a fire door, the BL5401SSDDA. Do you need MG Pro?
Yes. All BL5401 units are factory set for right hand doors. Remove the rubber grommet at the base of the keypad handle, use the included hex wrench to remove the grub screw, turn the handle 180 degrees and refit; repeat for the inside handle. Handing is read from the outside of the door: hinges on the right means right hand, hinges on the left means left hand, regardless of swing direction. No special tools beyond the included hex wrench are required; the handing chart is on page 1 of the ECP Instruction Segments (PDF).
Salt-air corrosion - the thing that quietly destroys standard door hardware within a couple of years on beachfront sites. The MG Pro build pairs 316 stainless steel internal components with the MG Pro 2 black external coating, and the assembly is tested to 1,000 continuous hours of salt spray - a laboratory result, which is why Borg backs the finish with a 12 month corrosion warranty rather than vague claims. The full MG / MG Pro / ECP naming system is decoded in MG Pro and ECP Explained, and the three brands are compared in Lockwood vs Borg vs Carbine.
Additional Information
Monthly: wipe the keypad, both levers and the exposed latch with a light spray of silicon-based lubricant (such as GT85) and remove the excess with a soft cloth. Do not use oil-based lubricants such as WD-40 - they attract dirt and wear down internal parts over time. In direct salt spray zones, rinse the external surfaces with fresh water periodically. Annually: remove the lock from the door, spray the inside through the button holes on the reverse of the keypad with silicon-based lubricant, spray all fixings, accessories and the latch, then press each button and operate both levers several times to confirm smooth operation. The routine keeps the corrosion warranty conditions met. Full steps are in the Borg Lock Servicing Guide (PDF), and how long digital locks last covers what decides lifespan.
The DDA flat bar lever meets the design requirements of AS1428.1-2009 for locking hardware in accessible environments. Full building compliance requires confirmation with a building certifier or access consultant. For NDIS and SDA projects, funding pathways for access hardware are covered in our NDIS guide - we can supply and install to NDIS participants; contact us to discuss.
This lock is not fire tested, so it is not for fire door assemblies. Borg's fire tested lever locks are the On The Bench BL5401SSDDA (the DDA flat bar lever) and the round bar BL5001, tested to AS 1905.1-2005 up to 4 hours depending on the type of doorset. On an older apartment fire door, read our asbestos warning before anyone drills, and our apartment fire door compliance guide for the wider picture.
Two spindles are supplied (80mm and 90mm). The general rule is door thickness plus 30mm for the minimum spindle length - at least 15mm must seat inside each handle. Use the longest spindle that fits; a spindle that is too short can disengage when the door is slammed. Spindle fitting by lock type is on page 3 of the ECP Instruction Segments (PDF), and our advice and installation service can take it from here.
If maximum cycle rating and corrosion resistance are the priority, the Carbine CDL7100SC (C7 salt spray, AS4145.2, rear BCA DDA lever) is worth comparing - a heavier commercial duty lockset suited to higher traffic sites. The BL5401 is the lighter, lower cost choice with on-door code change. See the DDA options in the heavy duty commercial locks guide and Chapter 16.
After any Easicode Pro code change, test the new code at least five times before closing the door. The change is confirmed only when the lever operates on the new code - there is no key override on this lock to get you back in. The safe testing procedure is in our code change guide.
Warranty
All Borg locks are warranted against mechanical defects in materials and workmanship under normal use and service for a minimum of 12 months from date of sale. The warranty does not cover damage arising from misuse, vandalism, or improper installation. The lock must not be dismantled - doing so will invalidate the warranty. Proof of purchase required for all claims.
Download PDF Resources
Borg's two-page brochure for the BL5400 ECP flat bar series - medium to heavy duty, retrofits third party lockcases, free turning flat bar lever, 100,000 cycle testing, the lock options (BL5401 tubular latch, BL5403 sash lockcase, BL5404 escape lockcase, BL5408 panic hardware, BL5409 night latch), technical information and dimensioned keypad and inside handle drawings.
Borg's two-page marine grade Easicode Pro brochure - the MG Pro 2 black finish, 316 stainless construction, 1,000 hour salt spray and 100,000 cycle testing, over 1,000 combinations; named for the BL5200 and BL5700 ECP models, it describes the Marine Grade Pro construction this BL5401 variant shares.
The Easicode Pro instructions as six one-page segments - preparation and handing (page 1), the deactivation plugs (page 2), spindle fitting with the 15mm blade engagement rule (page 3), the code change (page 4), daily operation (page 5) and identifying a lost code (page 6).
Borg's six-page manual for the BL5000 series Easicode Pro locks, the BL5400 flat bar keypad included - handing, the free passage and code change deactivation plugs, spindle fitting, the on-door code change, daily use and how to find a lost code.
One-page drilling template for the BL5000 platform tubular latch locks - 159mm hole centres with 60mm or 70mm backset marks for the through-door and latch preparation.
One-page accessories flyer for the BL5000 series - the keypad-only spares, the Lockwood 002, 3572 and 3582 conversion kits and the SPBL5001 scar plates. It dates from 2009, so check current item codes with us.
Borg's general maintenance guide for pushbutton keypad locks - monthly silicone-based lubricant care and an annual full service. This is the routine to follow for this lock.
Borg BL5401DDAMGPROECP - FAQ, Setup and Owner's Guide
Everything owners, installers and specifiers ask about the BL5401DDAMGPROECP DDA lever lock. For the wider category start with the Mechanical Digital Locks Buyer's Guide chapter; for DDA and NDIS context see Chapter 09 - DDA, NDIS and Accessibility.
Accessibility and Compliance
AS1428.1-2009 (Design for Access and Mobility) specifies minimum requirements for the design of facilities for people with disabilities. On this product, compliance relates specifically to the lever handle design - the flat bar format needs less grip force and wrist torque than a round bar or knob, within the standard's force thresholds for operable hardware. Compliance does not extend to the keypad or code entry, which needs finger pressure and manual dexterity. If full AS1428 compliance throughout the locking system is required, consult your access consultant. See AS1428 in Chapter 11.
Access consultants, builders and certifiers working on BCA-compliant projects: accessible toilets in commercial buildings, NDIS and SDA housing, healthcare and aged care, schools and clubs. The flat bar lever is the item that satisfies AS1428.1-2009 for the door hardware; the keypad is what removes key management from shared facilities. Our NDIS and disability housing guide walks through who signs off on what.
It may be eligible under assistive technology categories where DDA-compliant door hardware is specified in a participant's plan. Eligibility depends on the plan, the assessed need and the registered provider handling the claim. We can supply and install the lock to NDIS participants - contact us to discuss. See NDIS funding for DDA hardware and the NDIS funding section of Chapter 09.
Yes. The inside DDA lever is always free - no code, no key, no thought required to exit. Only the outside lever is code-controlled. This free egress behaviour is exactly what exit path compliance wants from an access-controlled door; the exit paths section of our commercial guide explains the requirements.
The BL5401DDAMGPROECP has not been fire tested, so it is not for fire doors - however compliant the lever is. The fire tested DDA lever lock is the On The Bench BL5401SSDDA (AS 1905.1-2005, up to 4 hours depending on the type of doorset). Strata and apartment installs have extra rules; see what a compliant fire door installation looks like and fire door types and certification.
Codes and Code Change
With the door open: (1) enter the existing code; (2) put the code change key over the code change button, turn it 90 degrees clockwise, press and hold; (3) press C to clear; (4) enter the new digits twice; (5) release the key, turn it back and remove it; (6) press C or turn the lever to set; (7) the new code is live; (8) test it at least five times before closing the door. If the new code fails, the old and new digits may have combined - enter both together and repeat from step 1. If the lever free-turns, the new code never set - repeat from step 2. Illustrated: page 4 of the ECP Instruction Segments (PDF) and our code changing guide.
Yes, with the keypad off the door. The back of the keypad has 10 portholes, one per button. Press C to reset, then read the markings through the portholes: red lines closest to the porthole centre are coded digits, blue lines are uncoded. Note the digits (there is no sequence - the coded buttons pressed in any order open the lock), refit the unit, then change the code on the door. Procedure with diagram: page 6 of the ECP Instruction Segments (PDF) - or we can do it for you.
Yes. The box includes an on-door code change deactivation plug - put it into the arrow-marked hole at the top centre of the keypad back (dome up) before installation, and the code can then only be changed with the unit off the door. Handy for managed sites where only maintenance should touch codes. Procedure: page 2 of the ECP Instruction Segments (PDF).
The mechanical coding chamber reads which buttons are depressed, not the sequence. That is why the combination pool is stated as over 1,000 rather than the millions an electronic keypad claims - it is an honest mechanical figure, and it also means an onlooker cannot infer the code from the order you press. Avoid obvious sets (1-2-3-4) and change the code when staff leave. Day-to-day: press C first to reset, enter the code, operate the lever. Any-order codes explained.
Installation and Setup
All BL5401 units ship factory set for right hand doors. Remove the rubber grommet at the base of the keypad handle, use the included hex wrench to remove the grub screw, turn the handle 180 degrees and refit; repeat for the inside handle. Handing is read from outside the door: hinges on the right is right hand, hinges on the left is left hand. Handing chart: page 1 of the ECP Instruction Segments (PDF).
The BL5401DDAMGPROECP comes with fixings for 35-54mm doors. For a thicker door, talk to us at order time about longer fixings and the spindle: the supplied 80mm and 90mm spindles cover the standard range, and at least 15mm of spindle must seat inside each handle.
Yes, on a standard timber door it is a competent-DIY job: the drilling template (PDF) gives the 159mm hole centres and the 60mm or 70mm backset lines, and the supplied M4 screws cover the 35-54mm door range. see our advice and installation service.
Usually yes - the 8mm square spindle suits most leading tubular latch and mortice lockcase brands, and the Lockwood 3572 and 3582 adaptor kits in the Accessories table mount the keypad onto those lockcases. Keep at least 15mm of spindle engaged in each handle when trimming. Confirm spindle compatibility with the lockcase manufacturer before specifying a multi-brand install; details on page 3 of the ECP Instruction Segments (PDF).
Suitability and Environment
Marine grade resists salt attack - it does not eliminate maintenance. Rinse external surfaces with fresh water periodically in direct salt spray zones, wipe monthly with a silicon-based lubricant (never oil-based), and do the annual internal service in the Borg Servicing Guide (PDF). That routine keeps the 12 month corrosion warranty conditions met and the finish performing well beyond it. The 1,000 hour salt spray figure in context.
For a genuinely high traffic public entrance - hundreds of cycles a day, every day - a maximum heavy duty lock is the better tool: the Carbine CDL7100SC keeps a rear DDA lever, and the Lockwood 3572DX or Borg BL7701 cover other doors. The BL5401 is a medium to heavy duty lock - 100,000 cycles covers offices, amenities and institutional doors comfortably, provided a servicing schedule is kept on busier doors. What heavy duty actually means.
No - the DDA flat bar lever is an accessibility lever, not an anti-ligature design. For behavioural health, correctional or other ligature-risk environments, use a purpose-built anti-ligature product such as the Borg BL2901SCECP anti-ligature knob.
Spares and the BL5401 Family
No. The BL5401KSSDDAECP spare ECP keypad is the direct replacement outside unit - the latch, inside handle and fixings stay on the door. The other DDA keypad also fits, but the coding chamber lives in the keypad, so fitting it changes the code change method (and both catalogued spares are satin stainless, not black MG Pro - contact us for a coastal replacement). The full spares set is in the Accessories table on the main tab, and why genuine spares availability matters is a story in itself.
Lockwood DX is the maximum heavy duty mortice benchmark, Carbine CDL7 is the value heavy duty lockset (the CDL7100SC even offers a rear DDA lever), and Borg owns the breadth - the only range with an on-door ECP code change and AS1428.1 DDA flat bar lever in one lock. The three-brand comparison: Lockwood vs Borg vs Carbine, and Borg's brand story is in Chapter 10.
Related Products, Guides and Chapters
BL5401 DDA family: BL5401SSDDA (On The Bench, fire tested) - BL5401SSDDAECP (Easicode Pro) - BL5401KSSDDAECP spare keypad - BL5401KSSDDA spare keypad
Same platform: BL5001 round bar (fire tested, 4 finishes) - BL5001MGPROECP - BL5701 (flat bar inside, key override) - BL5771MGPROECP (back-to-back, key both sides)
DDA and heavy duty alternatives: Carbine CDL7100SC (rear DDA lever) - Lockwood 3572DX - Borg BL7701 - Borg BL2901SCECP (anti-ligature)
Spares: BLSFTUMBLER - BLL500070 - SPBL5001 - SPBL5001MB - BL50013572K - BL50013582K - LB22 lock box - BL5000GASKET
Guides: Ch 09 - DDA, NDIS and Accessibility - Ch 05 - Fire Door Smart Locks - Ch 11 - Australian Standards - Buyer's Guide Ch 16: Mechanical Digital Locks - DDA Smart Locks for NDIS and Disability Housing - DDA options in Heavy Duty Commercial Locks - MG Pro and ECP Explained - Changing Codes - Fire Door Types and Certification - Lockwood vs Borg vs Carbine - Passage Mode vs Holdback Mode - Browse all mechanical digital locks
What's In The Box - Borg BL5401DDAMGPROECP
- Borg BL5401DDAMGPROECP outside keypad and DDA flat bar lever assembly (black MG Pro 2)
- Inside DDA flat bar lever handle assembly (black MG Pro 2)
- 60mm anti-thrust stainless steel tubular latch (12mm bolt projection)
- Strike plate and box keep
- Spindles - 80mm and 90mm supplied (use the longest that fits)
- M4 stainless steel fixing screws - 40mm, 50mm and 60mm options
- 4 x 16mm screws
- Easicode Pro code change key
- Code change deactivation plug (optional use)
- Free passage deactivation plug (optional use)
- Hex wrench (Allen key) for handing changes
- Handle screw rubber grommet
- Installation instructions
Borg BL5400 Series - Dimensions
Three drawings for the BL5401 DDA: the outside keypad and the inside DDA lever handle engineering drawings, and the series isometric drawing. Plates 177mm H x 48mm W; keypad 26mm deep with a 77mm projection; inside handle 18mm deep with a 53mm projection; levers 128mm. All measurements are from the Borg engineering drawings.
Borg BL5000 Series - Product Brochure
PDF Files - Borg BL5401DDAMGPROECP
Borg's two-page brochure for the BL5400 ECP flat bar series - medium to heavy duty, retrofits third party lockcases, free turning flat bar lever, 100,000 cycle testing, the lock options (BL5401 tubular latch, BL5403 sash lockcase, BL5404 escape lockcase, BL5408 panic hardware, BL5409 night latch), technical information and dimensioned keypad and inside handle drawings.
Borg's two-page marine grade Easicode Pro brochure - the MG Pro 2 black finish, 316 stainless construction, 1,000 hour salt spray and 100,000 cycle testing, over 1,000 combinations; named for the BL5200 and BL5700 ECP models, it describes the Marine Grade Pro construction this BL5401 variant shares.
The Easicode Pro instructions as six one-page segments - preparation and handing (page 1), the deactivation plugs (page 2), spindle fitting with the 15mm blade engagement rule (page 3), the code change (page 4), daily operation (page 5) and identifying a lost code (page 6).
Borg's six-page manual for the BL5000 series Easicode Pro locks, the BL5400 flat bar keypad included - handing, the free passage and code change deactivation plugs, spindle fitting, the on-door code change, daily use and how to find a lost code.
One-page drilling template for the BL5000 platform tubular latch locks - 159mm hole centres with 60mm or 70mm backset marks for the through-door and latch preparation.
One-page accessories flyer for the BL5000 series - the keypad-only spares, the Lockwood 002, 3572 and 3582 conversion kits and the SPBL5001 scar plates. It dates from 2009, so check current item codes with us.
Borg's general maintenance guide for pushbutton keypad locks - monthly silicone-based lubricant care and an annual full service. This is the routine to follow for this lock.
Borg Locks Warranty
Borg products sold in Australia are covered against mechanical defects in materials and workmanship under normal use and service. Warranty claims are handled by Terry's Tradies Pty Ltd and its associated websites, trading names, and subsidiaries.
Warranty Summary
What the Warranty Covers
- Mechanical defects in materials and workmanship
- Defects arising under normal use and service conditions
- Repair or replacement of defective units at the discretion of the Australian distributor (LSC)
What the Warranty Does Not Cover
- Damage arising from misuse, vandalism, or abuse
- Damage resulting from improper installation
- Locks that have been dismantled - dismantling invalidates the warranty
- Normal wear and tear
- Cosmetic damage not affecting function
How to Make a Claim
- Contact Terry's Tradies Pty Ltd first if you purchased through us or one of its associated trading names - we will assess the issue and manage the warranty process with LSC on your behalf. You do not need to contact LSC or Borg Locks UK directly.
- Have your proof of purchase ready (receipt or order confirmation).
- Warranty claims for Borg products in Australia are processed through LSC, the authorised Australian importer and distributor. Where an item is returned to LSC, freight charges must be prepaid and the item returned within the warranty period.
- If LSC finds the returned item to be defective, it will be repaired or replaced, and a detailed assessment report is provided to the customer after examination.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. The Borg manufacturer warranty above operates alongside - and does not limit - these statutory rights.
Confused? Overwhelmed? We get it.
Choosing the right smart lock can be genuinely tricky - door types, backsets, app platforms, compatibility with your existing hardware... there is a lot to consider. We have decades of experience fitting locks of all types, including smart locks, and we are happy to help.
Our expert recommendation service is free. Upload a few photos of your door and describe what you need, and one of our qualified locksmiths will give you a personalised recommendation.
Get Your Free Recommendation →How it works - three easy steps:
1. Upload photos
A few clear shots of your door, lock and frame - inside and out.
2. We assess
Our locksmith reviews your setup and requirements - door type, weather exposure, how you want to use it.
3. You get a recommendation
A personalised recommendation tailored to your door, budget and needs. No pressure, no upsell.
Also useful while you are deciding: