Skip to main content

ASSA ABLOY SMARTair Standalone Wall Reader – PIN & RFID (iCLASS)

SMARTair

Terry's In-Store Price $1,056.06
Terry's Online Price $777.38
(No reviews yet) Write a Review
SKU:
STK SNAR3KUSSB
UPC:
8414625965507
Availability:
Usually ships in 3 business days
Colour/Finish:
Silver
ASSA ABLOY Logo

ASSA ABLOY SMARTair Standalone Wall Reader - PIN Keypad and HID iCLASS RFID

At A Glance

At A Glance
RFID card or tagiCLASS Card / Fob PIN codePIN Code Openow phone keyOpenow Phone Key
Upgrade Option
Remote opening from Web ManagerRemote Opening
Not Available
FingerprintFingerprint
Not Available

The ASSA ABLOY SMARTair Standalone Wall Reader (SNAR3KUSSB) - catalogued by ASSA ABLOY as the SMARTair wall reader "PIN/Prox" - is a wired access control reader with a PIN keypad and an HID iCLASS card reader, for electric locks, automatic doors, gates and other controlled access points.

Users open with a code, an RFID credential or a combination of both, depending on how the reader is set up. In Standalone SMARTair mode the reader keeps its users and permissions itself and releases the connected electric strike or magnetic lock through its relay board - there is no network or software to run, and the site is set up with SMARTair programming cards (Product Overview).

It suits commercial buildings, industrial facilities, education campuses and other sites that want credential-based access control without network infrastructure. As the site grows, the reader can be upgraded to Update-on-Card and then Wireless Online by adding an RF module and a firmware upgrade (wall reader datasheet); the Wireless Online version with Openow is the SNZR3KUSSB. For the whole platform, see the SMARTair Wireless Access Control Overview.

Dispatch
Estimated Dispatch
Usually ships in 3 business days.
Wired power and locking device
What the wall reader needs to work
The reader and its relay board release a separate electromechanical device - an electric strike, electromagnetic lock or escape-route device - and cabling is needed (wall reader datasheet). Relay 1 commands that lock, which is not included, and the reader draws its 12-24 VAC/VDC power through the relay board from a supply you provide. On a door without electric locking, a battery-powered SMARTair i-max Standalone escutcheon or Standalone knob cylinder locks the door by itself.

Key Features

  • Standalone SMARTair wall reader - users, PIN codes and permissions are held in the reader, with no network or software to run.
  • Integrated PIN keypad and HID iCLASS card reader; read distance 2-4 cm.
  • Users open with a code, a credential or a combination of both, depending on how the reader is set up.
  • Relay board with two output relays: relay 1 commands the electric strike or magnetic lock, and relay 2 is configurable for another purpose.
  • Status inputs for door position (sensor not included), request to exit and tamper.
  • Suits electric strikes, electromagnetic locks, automated doors and escape-route devices.
  • Green and red LED indicators and buzzer for access granted and denied.
  • Up to 1,500 users and 600 events; a high-traffic door mode takes unlimited users in 48 groups and stores 1,000 events.
  • Real-time clock and calendar - 30 time zones of five periods, 20 operating-mode changes per door per day, automatic daylight saving, and 48 hours of clock backup from an internal battery.
  • Upgradeable from Standalone to Update-on-Card and then Wireless Online by adding an RF module and a firmware upgrade (R4 circuit required).
  • Openow phone keys can be added by fitting the Openow Bluetooth 4.2 module and a firmware upgrade.
  • IP55 wall reader rated for high traffic, in a durable housing designed for commercial environments; RCM and R-NZ marked.

Access Methods

How users get through the opening this reader controls, and what it does not do. Chapter 03 compares every method side by side.

Method Status Notes
RFID Card / Fob (HID iCLASS) Standard HID iCLASS 13.56 MHz cards and fobs, added at the reader with SMARTair programming cards on Standalone; read at 2-4 cm. The MURAL reader range also lists MIFARE Classic and Ultralight, SKIDATA and DESFire; this listing is the iCLASS version. See how RFID credentials work
PIN Code Built in PIN entry on the reader's keypad; users open with a code, a credential or a combination of both, depending on how the reader is set up. See PIN access explained
Openow Phone Key Upgrade option Added by fitting the Openow Bluetooth 4.2 module and a firmware upgrade, with the site then managed in TS1000 with the Openow mobile access licence; the Wireless Online version with Openow built in is the SNZR3KUSSB
Remote Opening Not Available Needs Wireless Online - upgrade the reader, or choose SNZR3KUSSB
Fingerprint Not Available SMARTair uses cards, tags, PINs and phone keys, not biometrics

Browse other card and fob access products and PIN code products.

What's Included

SNAR3KUSSB
  • SMARTair MURAL wall reader with keypad - HID iCLASS card reader and PIN keypad, black
  • SMARTair relay board in its surface-mount box - two output relays, inputs for door position and request to exit, and a tamper switch in the board
  • Installation mounting hardware
  • Setup and programming documentation

Not included: the power supply and cabling, the electric strike, electromagnetic lock or escape-route device (for relay 1), the door sensor, the exit push button, a DIN rail enclosure, RFID credentials, SMARTair programming cards, the encoder and the portable programmer.

Suitable Uses

ASSA ABLOY designed SMARTair wall readers for automated doors, turnstiles, barriers, lifts and any access whose locking or blocking element is automated (wall reader datasheet). Typical installations:

  • Doors with an electric strike or electromagnetic lock, and automatic doors.
  • Gates, turnstiles, barriers and lifts - any opening whose locking or blocking element is electrically operated.
  • Escape routes, where the relay board drives the escape-route device.
  • Commercial buildings, industrial facilities and education campuses.
  • High-traffic openings - ASSA ABLOY rates the reader for high traffic volume.
  • Sites that want PIN, card or card + PIN access without network infrastructure.
  • Mixed SMARTair sites - the reader sits alongside escutcheons, knob cylinders and i-gate padlocks, and management tiers can be combined on one site (system architecture).
Not suitable for
Not suitable for
  • Doors without electric locking - a SMARTair i-max Standalone escutcheon or Standalone knob cylinder locks the door by itself on battery power.
  • Sites running MIFARE cards - this listing is the HID iCLASS version; for MIFARE, see the seven i-Reader R4N readers, such as the S4ZR2DSlim and S4ZR2PWide (Wireless Online + Openow) and the S4BR2Slim1 and S4BR2Wide1 (Update-on-Card + Openow).
  • Openings without a 12-24 VAC/VDC supply and cabling to the relay board.
  • Mounting the relay board outside - the IP55 rating is for the wall reader.
  • Sites that want central management, live audit collection, or phone keys from day one without adding the Openow module - choose the Wireless Online + Openow SNZR3KUSSB.

Available Finish Options

  • Black
    Black
    (This Product)
    STK SNAR3KUSSB

Finish selection does not affect functionality, compliance, or performance.

We list the MURAL wall reader in black, as pictured on the wall reader datasheet.

SMARTair Wall Reader Comparison

The two SMARTair keypad wall readers we list share the MURAL reader, the HID iCLASS card reader and the relay board, and differ by management tier. This product's column is in bold.

Feature SNAR3KUSSB (This Product)
Standalone Wall Reader
SNZR3KUSSB
Wireless/Openow Wall Reader
SMARTair System Architecture Standalone Wireless Online + Openow
Credential Technology HID iCLASS HID iCLASS
Keypad Yes Yes
Card + PIN Code, credential or both, depending on set-up Yes - card then PIN, or PIN then card
Mobile Access Optional - Openow Bluetooth 4.2 module and firmware upgrade Openow smartphone credentials
System Communication Local device storage Wireless communication via SMARTair hubs
Access Management Configured at the reader, with programming cards Managed centrally through SMARTair software
Relay Outputs 2 (relay 1 for the lock, relay 2 configurable) 2 (relay 1 for the lock, relay 2 configurable)
Time Zones 30 (five periods each) 14 (five periods each)
Remote Opening and Lockdown No Yes - Web Manager, TS1000 Lockdown Upgrade
Typical Applications Single doors or small sites without a network Networked buildings with central access control
RFID credentials
MIFARE vs HID iCLASS - What's the Difference?
Both are secure 13.56 MHz RFID credential technologies used in commercial access control. MIFARE is widely used in commercial access systems, universities, transport cards and multi-application credentials. HID iCLASS is HID's own credential platform, used in many enterprise security systems. The reader technology must match the credentials used in the building's access control system - the i-Reader R4N readers read MIFARE, and the MURAL keypad readers we list are the HID iCLASS versions. If you're not sure which your site uses, send us a sample card and we will check it before you order.

System Integration

  • Standalone management: the reader holds its own users, PIN codes and permissions, and the site is set up with SMARTair programming cards rather than software (devices you need).
  • On Standalone, lost cards are cancelled by hand and credentials can't carry activation or expiry dates - both come with the managed tiers (feature comparison).
  • The yearly calendar is updated once a year with the portable programmer, and daylight saving changes are automatic.
  • Emergency opening and service: a jack connection takes the portable programmer and emergency kit (wall reader datasheet).
  • Upgrade path: Standalone, then Update-on-Card, then Wireless Online - by adding an RF module and a firmware upgrade; the R4 circuit is required (wall reader datasheet).
  • Works alongside the rest of SMARTair. On a Standalone site the reader sits alongside the SMARTair Standalone knob cylinders (SNAB43X030E10MI black, SNAW43X030E10MI white) and i-max Standalone escutcheons (SNAB43SL2V648DI, SNAB43SL2V908DI, SNAB47SL2V648DI, SNAB47SL2V908DI) - all HID iCLASS, so the same cards open every door, and all are set up with programming cards.
Standalone
Standalone - when it fits
A Standalone reader is set up and changed at the door, so it suits a small number of openings with a stable user list. Once the site wants central management, automatic cancellation of lost cards, audit collection or phone keys, the reader can be upgraded, or you can start with the Wireless Online + Openow SNZR3KUSSB. See the SMARTair System Information Guide for how the tiers compare.

How the SMARTair Standalone Reader is Used

In Standalone mode the reader stores user credentials and PIN codes itself. When a valid credential or PIN is presented, it switches its relay output to unlock the connected door or access control device.

  1. Install the reader on the wall near the door or gate, with the relay board on the secure side.
  2. Connect relay 1 on the relay board to the electric strike, electromagnetic lock or door automation controller.
  3. Program the authorised PIN codes and RFID credentials using SMARTair programming cards.
  4. Users gain access by presenting a credential, entering a PIN, or both, depending on how the reader is set up.

Standalone readers suit locations that need a simple, reliable electronic access solution without connecting to a centralised access control network.

Full Specifications

Brand ASSA ABLOY - SMARTair (commercial brand profiles)
Item Code SNAR3KUSSB
Product Type Wired wall reader with PIN keypad and HID iCLASS card reader (SMARTair MURAL) - drives an external locking device through its relay board
Management Tier Standalone - upgradeable to Update-on-Card, then Wireless Online, by adding an RF module and a firmware upgrade (R4 circuit required)
RFID Technology HID iCLASS, 13.56 MHz; the MURAL reader range also lists MIFARE Classic and Ultralight, SKIDATA and DESFire
Read Range 2-4 cm for standard RFID credentials
Keypad and PIN Integrated keypad for PIN entry
Card and PIN Code, credential or a combination of both, depending on how the reader is set up
Mobile Access Optional - Openow added with the Openow Bluetooth 4.2 module and a firmware upgrade
Remote Opening No - Standalone reader
User Capacity Normal mode 1,500 users and 600 events; high-traffic door - unlimited users filtered into 48 groups, 1,000 events
Time Zones and Calendar 30 time zones with 5 periods each; state tables for 20 operating-mode changes per door per day; yearly calendar updated once a year with the portable programmer; daylight saving automatic
Clock Backup Clock and calendar maintained for 48 hours without power (internal backup battery)
Operating Modes Standard (open 4-10 seconds, configurable); Standard ADA (double opening time); Passage; Double user; First user
Status Indication Green / red LED and buzzer
Emergency Opening Jack connection for the portable programmer and emergency kit
Power Cabled 12-24 VAC/VDC through the relay board; max 500 mA @ 12 V / 250 mA @ 24 V (reader + relay board); power supply not included
Relay Board Two output relays - relay 1 commands the lock (not included), relay 2 configurable by dip switch or, on a managed site, in the management software; inputs for door position (sensor not included) and request to exit; tamper switch in the board; surface-mount box, DIN-rail mountable (enclosure not included), 120.5 x 105.5 x 36 mm
Other Relay Boards Simple 1-relay board (reduced size) and 8-output relay board for lifts - up to 5 in series for 40 outputs - available as spare parts
Security Encrypted communication between reader and relay board - no manipulation of the wiring between them can open the door
Dimensions Reader 121 mm high x 77 mm wide x 25 mm deep; relay board 120.5 x 105.5 x 36 mm
Environmental Rating IP55 (wall reader) - IP ratings explained
Operating Environment Reader -20 to +80 degrees C; relay board -10 to +80 degrees C; up to 85 percent humidity
Traffic Volume High
Certifications CE (EMC, R&TTE), RoHS, REACH, WEEE, RCM and R-NZ (what RCM means)
Finish Black
Lead Time Usually ships in 3 business days
Warranty ASSA ABLOY - 10 years mechanical, 5 years electrical and electronic (batteries excluded)

The MURAL reader, relay board, power, environmental and certification data is shared across the MURAL wall reader range and comes from the wall reader datasheet, which documents the version without a keypad; the keypad and PIN details are specific to this keypad version.

Frequently Asked Questions

What else do I need to make the wall reader work?
An electric strike, electromagnetic lock or escape-route device for relay 1 to command, a 12-24 VAC/VDC power supply and cabling to the relay board - plus SMARTair programming cards to set it up. See What's Included.
Can users open with a card, a PIN or both?
Yes - users open with a code, an HID iCLASS credential or a combination of both, depending on how the reader is set up.
Does it need a network, hubs or software?
No. In Standalone mode the reader holds its own users and permissions and is set up with programming cards (Product Overview). If you later want central management, it can be upgraded to Update-on-Card and then Wireless Online (wall reader datasheet); adding Openow also brings in TS1000 and the Openow mobile access licence.
Can users open it with their phone?
Not as listed. Openow can be added by fitting the Openow Bluetooth 4.2 module and a firmware upgrade, with the site then managed in TS1000 with the Openow mobile access licence - or choose the Wireless Online + Openow SNZR3KUSSB, which has Openow built in.

Additional Information

  • Dispatch and planning. This reader usually ships in 3 business days. Order the rest of the job at the same time - the strike or lock, the power supply, programming cards and credentials - so it can be commissioned in one visit.
  • Plan the power and cabling. The reader runs from a 12-24 VAC/VDC supply through its relay board, and the relay switches the lock without powering it, so the strike or magnetic lock needs its own supply. Choose a fail-safe or fail-secure locking device to suit the opening. It is a job for an experienced access control installer - see advice and installation.
  • Keep the programming cards safe. A Standalone reader is set up and changed with SMARTair programming cards, and lost cards are cancelled by hand on this tier (feature comparison) - store the cards securely and record who holds which credential.
  • Match the credential first. This listing reads HID iCLASS; the MIFARE equivalents are the i-Reader R4N readers. If the site already has cards, send us a sample before ordering.
  • Data and support. On Standalone, users, PINs and events are held in the reader itself. When the site moves to a managed tier, TS1000 keeps the site database on your own server (Product Overview). For where access platforms keep data, see platforms hosted outside China.

Warranty

Warranty
ASSA ABLOY Warranty (Australia)
ASSA ABLOY branded products purchased new in Australia from authorised resellers are covered against defects in materials and workmanship for:
  • Mechanical components: 10 years
  • Electrical and electronic components: 5 years (excluding batteries)
  • Cylinders and keys: 3 years
Cosmetic finishes, batteries, normal wear and tear, misuse, unauthorised modification, corrosion and labour or freight costs are excluded. Proof of purchase required for all claims.
This warranty operates in addition to rights available under the Australian Consumer Law.

Download PDF Resources

SMARTair Standalone Wall Reader Datasheet (PDF)
ASSA ABLOY's technical information for the SMARTair MURAL wall reader in its version without a keypad - the technical data, reader module and control unit, operating modes, the two-relay board and the dimension drawing it shares with this keypad reader.
SMARTair Wireless Access Control Product Overview (PDF)
The May 2023 technical overview - the four management systems and the equipment each needs, the feature comparison, system architecture, TS1000 and Web Manager, credentials, and the wall reader in the other-devices table on page 10.
SMARTair System Information Guide (PDF)
The May 2022 benefits guide - the management levels with decision guidance on page 4 (Pro Wireless Online with the hub coverage note, Openow and Update-on-Card), Openow virtual keys and the wall reader device page.
ASSA ABLOY Logo

SMARTair Standalone Wall Reader (SNAR3KUSSB) - FAQ, Set-Up and Owner's Guide

Everything below is here to help you choose, install and run this reader. For general smart lock questions see our Smart Lock FAQ (Chapter 13), and for the wider picture start with the Buyer's Guide.

Choosing This Reader

What is the SNAR3KUSSB?
It is SMARTair's Standalone wall reader with a PIN keypad and an HID iCLASS card reader. It holds its own users and permissions, needs no network, and releases an electric strike, magnetic lock or door operator through its relay board.
How do the two SMARTair keypad wall readers differ?
By management tier. The SNAR3KUSSB is Standalone - no network, set up with programming cards - and the SNZR3KUSSB is Wireless Online + Openow, managed centrally in TS1000 through SMARTair hubs. Both read HID iCLASS and have a keypad. See the wall reader comparison.
Do I need a keypad wall reader or an i-Reader?
A keypad wall reader if you want PIN entry or card + PIN, and your site runs HID iCLASS. The i-Reader R4N readers - for example the S4ZR2DSlim or S4ZR2PWide - have no keypad and read MIFARE, in Slim and Wide formats.
Is the reader a lock?
No. It checks the credential and switches a relay; the lock is a separate electric strike, electromagnetic lock, escape-route device or door operator wired to the relay board (wall reader datasheet). On a door without electric locking, a battery-powered SMARTair i-max Standalone escutcheon or Standalone knob cylinder locks the door by itself.
Is there a higher-spec version?
The SNZR3KUSSB is the Wireless Online + Openow version. It costs more, and in return changes and events travel in real time through SMARTair hubs, and Openow phone keys are enabled.

Cards, Tags and Credentials

Which cards and fobs does it read?
HID iCLASS 13.56 MHz cards and fobs, added at the reader with SMARTair programming cards on Standalone. The MURAL reader range also lists MIFARE Classic and Ultralight, SKIDATA and DESFire; this listing is the iCLASS version. Browse RFID cards, fobs and tags.
Will it read my building's existing cards?
Only if they are HID iCLASS. An existing card of the right type can often carry SMARTair data too, because SMARTair uses the credential's free memory alongside other services (Product Overview) - send us a sample card and we will check it.
How close does the card need to be?
2-4 cm for standard RFID credentials (wall reader datasheet). See how RFID credentials work.
What happens when a card is lost or stolen?
On a Standalone site the card is cancelled by hand - automatic cancellation of lost cards is a feature of the managed tiers, not Standalone (feature comparison). Keep a record of who holds which credential.
Can I limit access to certain times?
Yes - the reader holds 30 time zones with five periods each, and state tables can change its operating mode up to 20 times a day. Activation and expiry dates on credentials come with the managed tiers, not Standalone (feature comparison).
Can users open with a PIN, a card or both?
Yes - users open with a code, an HID iCLASS credential or a combination of both, depending on how the reader is set up. See PIN access explained.

Openow Phone Keys

What is Openow?
ASSA ABLOY's mobile credential: a virtual key in the Openow app, used over Bluetooth. Keys are sent, revoked and updated over the air, are end-to-end encrypted, and a cancelled key vanishes from the phone (Information Guide).
Can I add Openow to this reader later?
Yes - by fitting the Openow Bluetooth 4.2 module and a firmware upgrade. Openow keys are issued from TS1000 with the Openow mobile access licence, so the site moves from programming-card set-up to TS1000 management. If phone keys are a must from day one, the Wireless Online + Openow SNZR3KUSSB has Openow built in.
What does a site need to use Openow?
The Openow mobile access licence enabled in TS1000, users with the Openow app on their phones, and TS1000's cloud connection, which carries keys to phones over HTTPS 443 (system architecture).
How does a user open the door with a phone?
They open the Openow app, press the padlock and hold the phone to the reader. Green means opened, orange means the phone could not connect (try again) and red means no access - no rights, a blocked door or outside the time schedule (Openow User Guide; February 2019, so screens may differ from today's app).

Standalone Set-Up and Upgrades

How is a Standalone reader set up?
With SMARTair programming cards - the Standalone tier needs only the door devices and a programming card, with no software licence, encoder or hubs (Product Overview).
Which programming card does it use?
We list the SMARTair Standalone Programming Card - iCLASS. Ask us if your site already has Standalone programming cards.
Can the reader be upgraded later?
Yes. SMARTair wall readers can be upgraded from Standalone to Update-on-Card and then Wireless Online by adding an RF module and a firmware upgrade; the R4 circuit is required (wall reader datasheet).
Does the calendar need updating?
Once a year, with the portable programmer; daylight saving changes are automatic, and the clock and calendar are held for 48 hours without power by an internal backup battery (wall reader datasheet).
What is the jack connection for?
Emergency opening and service - it takes the portable programmer and the emergency kit (wall reader datasheet).

Wiring, Power and Installation

What power supply does it need?
A 12-24 VAC/VDC supply, connected through the relay board. Maximum consumption for the reader and relay board together is 500 mA at 12 V or 250 mA at 24 V (wall reader datasheet). The power supply is not included.
What do the two relays do?
Relay 1 commands the electromechanical lock, which is not included, and relay 2 can be used for other purposes - its function is set on the board's dip switch, or in the management software on a managed site (wall reader datasheet). A smaller single-relay board and an 8-output lift board are available as spare parts.
Fail-safe or fail-secure - which lock should I use?
It depends on the opening. A fail-safe lock releases when power is lost and a fail-secure lock stays locked, so the choice follows the opening's exit and security needs. We will help you pick the strike or magnetic lock when we quote.
Can it use a door sensor and an exit button?
Yes. The relay board has inputs for a door position sensor - so intrusion or a door left open is reported - and a request-to-exit push button, plus a tamper switch in the board itself. The sensor and button are not included (wall reader datasheet).
Where does the relay board go?
On the secure side of the opening, away from the weather - the IP55 rating covers the wall reader. It comes in a box for surface mounting, and the board can also go on a DIN rail (enclosure not included; the tamper switch must then be overridden or added separately) (wall reader datasheet).
Can someone open the door by tampering with the reader?
The reader-to-relay-board communication is encrypted, so no manipulation of the wiring between the two can open the door (wall reader datasheet).
What happens in a power cut?
The reader and relay board stop until power returns, while users and events stay in non-volatile memory and the clock is held for 48 hours by an internal backup battery (wall reader datasheet). What the door does depends on the lock - see what actually happens in a power outage.
Who should install it?
An experienced access control installer - it is a wired job with a power supply, a relay board and an electric lock to set up, and the reader then has to be initialised and commissioned in SMARTair. See when DIY makes sense, our advice and installation and professional installation.

Operating Modes and Settings

What operating modes are there?
Standard; Standard ADA (standard operation with double opening time, for accessible doors); Passage (always open, set by time zone or by an authorised user after double badging); Double user (two valid credentials needed); and First user (standard until the first valid user enters, then passage until closed by an authorised user or a time zone) (wall reader datasheet).
How long does the door stay released?
In standard mode the opening time is configurable from 4 to 10 seconds, and the ADA mode doubles it (wall reader datasheet).
What do the LED and buzzer show?
The green and red LED and the buzzer signal access authorised or denied (wall reader datasheet).
Can the mode change through the day?
Yes - state tables can change the operating mode up to 20 times per door per day, for example passage mode during business hours (wall reader datasheet).

Outdoor Use and Environment

Can the reader be mounted outside?
The wall reader is IP55 rated, for -20 to +80 degrees C and up to 85 percent humidity; the relay board is rated -10 to +80 degrees C and belongs on the secure side (wall reader datasheet). See IP ratings explained.
Is it suitable near the coast?
The IP rating covers water and dust, not salt air, and ASSA ABLOY doesn't quote a salt spray figure for the reader. Its warranty excludes corrosion, so on the coast choose a sheltered position and check the reader regularly - see coastal environments and what coastal Queensland does to locks.

Software and System Management

Does a Standalone reader need software?
No - it is set up with programming cards (Product Overview). TS1000 and Web Manager come in when the site moves to Update-on-Card or Wireless Online (software).
Can one site mix tiers and device types?
Yes. SMARTair management systems can be combined on one site (system architecture), so a building can run different tiers where they suit. On a Standalone site the reader sits alongside the SMARTair Standalone knob cylinders (SNAB43X030E10MI black, SNAW43X030E10MI white) and i-max Standalone escutcheons (SNAB43SL2V648DI, SNAB43SL2V908DI, SNAB47SL2V648DI, SNAB47SL2V908DI) - all HID iCLASS, so the same cards open every door, and all are set up with programming cards.
How many users and events does it hold?
1,500 users and 600 events in normal mode, or unlimited users filtered into 48 groups with 1,000 events on a high-traffic door (wall reader datasheet).
Can the firmware be updated?
Yes - the control unit has upgradeable firmware (wall reader datasheet).
Where is the data kept?
On Standalone, users, PINs and events are held in the reader itself; if the site moves to a managed tier, TS1000 keeps the site database on your own server (Product Overview). For how access platforms compare on data hosting, see platforms hosted outside China and security and data sovereignty.

Compliance, Warranty and Ordering

What certifications does it carry?
CE (EMC, R&TTE), RoHS, REACH, WEEE, RCM and R-NZ (wall reader datasheet). See Chapter 11 for what RCM means in Australia.
What warranty applies?
ASSA ABLOY's Australian warranty - 10 years on mechanical components and 5 years on electrical and electronic components, batteries excluded. The full terms are in the Warranty section.
How long does dispatch take?
This reader usually ships in 3 business days. Order the lock, power supply and programming cards at the same time so the opening can be commissioned in one visit.

Related Products, Guides and Chapters

The other keypad wall reader: SNZR3KUSSB (Wireless Online + Openow keypad reader)

The MIFARE i-Reader R4N range: S4BR2Slim2 (i-Reader Slim, Update-on-Card) · S4BR2Slim1 (i-Reader Slim, Update-on-Card + Openow) · S4BR2Slim3 (i-Reader Slim, Wireless Online) · S4ZR2DSlim (i-Reader Slim, Wireless Online + Openow) · S4BR2Wide2 (i-Reader Wide, base) · S4BR2Wide1 (i-Reader Wide, Update-on-Card + Openow) · S4ZR2PWide (i-Reader Wide, Wireless Online + Openow)

Devices for the same site: SNAB43X030E10MI · SNAW43X030E10MI · SNAB43SL2V648DI · SNAB43SL2V908DI · SNAB47SL2V648DI · SNAB47SL2V908DI

System components: Encoder - USB RFID Credential Programmer STCED3 · Portable Programmer STCPCC · Standalone Programming Card - iCLASS SNACLICSTAIC · Mobile Access Licence - Openow SNCCLICMOBILE

Categories: Fob / Card / RFID · RFID / Fobs / Tags / Cards · PIN Code

Buyer's Guide chapters: Ch 03 Access Methods · Ch 04 Door Types · Ch 08 Gateways · Ch 09 Accessibility · Ch 10 Brand Profiles · Ch 11 Standards and IP Ratings · Ch 12 Troubleshooting · Ch 13 FAQ · Ch 15 App Platforms

Helpful blog reading: Power Outages and Electronic Locks · The Realities of Electronic Door Locks · How Long Do Digital Door Locks Last? · Which Platform for Commercial Sites? · Your Data and China · Site Survey and Installation

ASSA ABLOY Logo

What's in the Box - SNAR3KUSSB

  • SMARTair MURAL wall reader with keypad - HID iCLASS card reader and PIN keypad, black
  • SMARTair relay board in its surface-mount box - two output relays, inputs for door position and request to exit, and a tamper switch in the board
  • Installation mounting hardware
  • Setup and programming documentation
Not included: the power supply and cabling, the electric strike, electromagnetic lock or escape-route device (for relay 1), the door sensor, the exit push button, a DIN rail enclosure, RFID credentials, SMARTair programming cards, the encoder and the portable programmer. The reader is set up with SMARTair programming cards; no software or network is needed on Standalone.
ASSA ABLOY Logo

PDF Files - SNAR3KUSSB

SMARTair Standalone Wall Reader Datasheet (PDF)
ASSA ABLOY's technical information for the SMARTair MURAL wall reader in its version without a keypad - the technical data, reader module and control unit, operating modes, the two-relay board and the dimension drawing it shares with this keypad reader.
SMARTair Wireless Access Control Product Overview (PDF)
The May 2023 technical overview - the four management systems and the equipment each needs, the feature comparison, system architecture, TS1000 and Web Manager, credentials, and the wall reader in the other-devices table on page 10.
SMARTair System Information Guide (PDF)
The May 2022 benefits guide - the management levels with decision guidance on page 4 (Pro Wireless Online with the hub coverage note, Openow and Update-on-Card), Openow virtual keys and the wall reader device page.

ASSA ABLOY Warranty Overview

ASSA ABLOY branded products sold in Australia are covered by manufacturer warranties issued by ASSA ABLOY Australia Pty Ltd. Warranty coverage varies depending on mechanical components, electronic components, cylinders and finish categories.

This overview summarises the structure of ASSA ABLOY warranty coverage. Full terms, exclusions and claim procedures are set out in the official ASSA ABLOY Warranty document.

Warranty Summary Icon Warranty Periods Summary

Coverage Area Warranty Period Notes
Mechanical components 10 years Applies to defects in material and workmanship.
Electrical & electronic components 5 years Excludes batteries.
Cylinders & keys 3 years Mechanical and electromechanical cylinders and keys.
Finishes Not covered Cosmetic or appearance damage excluded.

Finish Coverage Icon Finish & Material Notes

  • Stainless steel does not mean stain-free. Tea staining is not covered where cleaning and maintenance guidelines have not been followed.
  • Cosmetic, decorative and appearance damage is not covered.
  • Battery failure or battery leakage damage is not covered.

Coverage Icon What the Warranty Covers

  • Defects in material and workmanship within the applicable period.
  • Assessment by ASSA ABLOY to determine repair, replacement with the same or closest equivalent product, or refund of purchase price.
  • Remedy determined at ASSA ABLOY’s discretion.

Exclusions Icon Common Exclusions

  • Normal wear and tear.
  • Misuse, abuse or installation outside published technical specifications.
  • Improper maintenance or neglect.
  • Unauthorised modification or repair.
  • Use of non-genuine ASSA ABLOY parts or substitute components.
  • Exposure to corrosive environments including coastal air, salt spray, chemicals, contamination or high humidity.
  • Removal, refitment, freight or labour charges.
  • Second-hand or imported products not sold through authorised Australian channels.

Claim Process Icon Warranty Claim Process

  1. Retain proof of original purchase.
  2. Return the product to the original authorised retailer where applicable.
  3. If claiming directly, obtain a case number before returning goods.
  4. Securely package returned goods and clearly reference the case number.
  5. Warranty assessment determines repair, replacement or refund.

Australian Consumer Law Icon Australian Consumer Law

ASSA ABLOY warranties operate in addition to rights available under the Australian Consumer Law. Goods come with guarantees that cannot be excluded. Customers may be entitled to a replacement or refund for a major failure and compensation for reasonably foreseeable loss or damage.

Where a product fails to meet acceptable quality standards and the failure does not amount to a major failure, the customer is entitled to repair or replacement.

PDF Icon Official Warranty Documents

Ask our expert locksmith - 30 years experience

Confused? Overwhelmed? We get it.

Choosing the right smart lock can be genuinely tricky - door types, backsets, app platforms, compatibility with your existing hardware... there is a lot to consider. We have decades of experience fitting locks of all types, including smart locks, and we are happy to help.

Our expert recommendation service is free. Upload a few photos of your door and describe what you need, and one of our qualified locksmiths will give you a personalised recommendation.

Get Your Free Recommendation →

How it works - three easy steps:

1. Upload photos

A few clear shots of your door, lock and frame - inside and out.

2. We assess

Our locksmith reviews your setup and requirements - door type, weather exposure, how you want to use it.

3. You get a recommendation

A personalised recommendation tailored to your door, budget and needs. No pressure, no upsell.

Also useful while you are deciding: