ASSA ABLOY SMARTair Standalone Wall Reader - PIN Keypad and HID iCLASS RFID
At A Glance
Upgrade Option
Not Available
Not Available
The ASSA ABLOY SMARTair Standalone Wall Reader (SNAR3KUSSB) - catalogued by ASSA ABLOY as the SMARTair wall reader "PIN/Prox" - is a wired access control reader with a PIN keypad and an HID iCLASS card reader, for electric locks, automatic doors, gates and other controlled access points.
Users open with a code, an RFID credential or a combination of both, depending on how the reader is set up. In Standalone SMARTair mode the reader keeps its users and permissions itself and releases the connected electric strike or magnetic lock through its relay board - there is no network or software to run, and the site is set up with SMARTair programming cards (Product Overview).
It suits commercial buildings, industrial facilities, education campuses and other sites that want credential-based access control without network infrastructure. As the site grows, the reader can be upgraded to Update-on-Card and then Wireless Online by adding an RF module and a firmware upgrade (wall reader datasheet); the Wireless Online version with Openow is the SNZR3KUSSB. For the whole platform, see the SMARTair Wireless Access Control Overview.
Usually ships in 3 business days.
The reader and its relay board release a separate electromechanical device - an electric strike, electromagnetic lock or escape-route device - and cabling is needed (wall reader datasheet). Relay 1 commands that lock, which is not included, and the reader draws its 12-24 VAC/VDC power through the relay board from a supply you provide. On a door without electric locking, a battery-powered SMARTair i-max Standalone escutcheon or Standalone knob cylinder locks the door by itself.
Key Features
- Standalone SMARTair wall reader - users, PIN codes and permissions are held in the reader, with no network or software to run.
- Integrated PIN keypad and HID iCLASS card reader; read distance 2-4 cm.
- Users open with a code, a credential or a combination of both, depending on how the reader is set up.
- Relay board with two output relays: relay 1 commands the electric strike or magnetic lock, and relay 2 is configurable for another purpose.
- Status inputs for door position (sensor not included), request to exit and tamper.
- Suits electric strikes, electromagnetic locks, automated doors and escape-route devices.
- Green and red LED indicators and buzzer for access granted and denied.
- Up to 1,500 users and 600 events; a high-traffic door mode takes unlimited users in 48 groups and stores 1,000 events.
- Real-time clock and calendar - 30 time zones of five periods, 20 operating-mode changes per door per day, automatic daylight saving, and 48 hours of clock backup from an internal battery.
- Upgradeable from Standalone to Update-on-Card and then Wireless Online by adding an RF module and a firmware upgrade (R4 circuit required).
- Openow phone keys can be added by fitting the Openow Bluetooth 4.2 module and a firmware upgrade.
- IP55 wall reader rated for high traffic, in a durable housing designed for commercial environments; RCM and R-NZ marked.
Access Methods
How users get through the opening this reader controls, and what it does not do. Chapter 03 compares every method side by side.
Browse other card and fob access products and PIN code products.
What's Included
- SMARTair MURAL wall reader with keypad - HID iCLASS card reader and PIN keypad, black
- SMARTair relay board in its surface-mount box - two output relays, inputs for door position and request to exit, and a tamper switch in the board
- Installation mounting hardware
- Setup and programming documentation
Not included: the power supply and cabling, the electric strike, electromagnetic lock or escape-route device (for relay 1), the door sensor, the exit push button, a DIN rail enclosure, RFID credentials, SMARTair programming cards, the encoder and the portable programmer.
Suitable Uses
ASSA ABLOY designed SMARTair wall readers for automated doors, turnstiles, barriers, lifts and any access whose locking or blocking element is automated (wall reader datasheet). Typical installations:
- Doors with an electric strike or electromagnetic lock, and automatic doors.
- Gates, turnstiles, barriers and lifts - any opening whose locking or blocking element is electrically operated.
- Escape routes, where the relay board drives the escape-route device.
- Commercial buildings, industrial facilities and education campuses.
- High-traffic openings - ASSA ABLOY rates the reader for high traffic volume.
- Sites that want PIN, card or card + PIN access without network infrastructure.
- Mixed SMARTair sites - the reader sits alongside escutcheons, knob cylinders and i-gate padlocks, and management tiers can be combined on one site (system architecture).
- Doors without electric locking - a SMARTair i-max Standalone escutcheon or Standalone knob cylinder locks the door by itself on battery power.
- Sites running MIFARE cards - this listing is the HID iCLASS version; for MIFARE, see the seven i-Reader R4N readers, such as the S4ZR2DSlim and S4ZR2PWide (Wireless Online + Openow) and the S4BR2Slim1 and S4BR2Wide1 (Update-on-Card + Openow).
- Openings without a 12-24 VAC/VDC supply and cabling to the relay board.
- Mounting the relay board outside - the IP55 rating is for the wall reader.
- Sites that want central management, live audit collection, or phone keys from day one without adding the Openow module - choose the Wireless Online + Openow SNZR3KUSSB.
Available Finish Options
Black
(This Product)
STK SNAR3KUSSB
Finish selection does not affect functionality, compliance, or performance.
We list the MURAL wall reader in black, as pictured on the wall reader datasheet.
SMARTair Wall Reader Comparison
The two SMARTair keypad wall readers we list share the MURAL reader, the HID iCLASS card reader and the relay board, and differ by management tier. This product's column is in bold.
Both are secure 13.56 MHz RFID credential technologies used in commercial access control. MIFARE is widely used in commercial access systems, universities, transport cards and multi-application credentials. HID iCLASS is HID's own credential platform, used in many enterprise security systems. The reader technology must match the credentials used in the building's access control system - the i-Reader R4N readers read MIFARE, and the MURAL keypad readers we list are the HID iCLASS versions. If you're not sure which your site uses, send us a sample card and we will check it before you order.
System Integration
- Standalone management: the reader holds its own users, PIN codes and permissions, and the site is set up with SMARTair programming cards rather than software (devices you need).
- On Standalone, lost cards are cancelled by hand and credentials can't carry activation or expiry dates - both come with the managed tiers (feature comparison).
- The yearly calendar is updated once a year with the portable programmer, and daylight saving changes are automatic.
- Emergency opening and service: a jack connection takes the portable programmer and emergency kit (wall reader datasheet).
- Upgrade path: Standalone, then Update-on-Card, then Wireless Online - by adding an RF module and a firmware upgrade; the R4 circuit is required (wall reader datasheet).
- Works alongside the rest of SMARTair. On a Standalone site the reader sits alongside the SMARTair Standalone knob cylinders (SNAB43X030E10MI black, SNAW43X030E10MI white) and i-max Standalone escutcheons (SNAB43SL2V648DI, SNAB43SL2V908DI, SNAB47SL2V648DI, SNAB47SL2V908DI) - all HID iCLASS, so the same cards open every door, and all are set up with programming cards.
A Standalone reader is set up and changed at the door, so it suits a small number of openings with a stable user list. Once the site wants central management, automatic cancellation of lost cards, audit collection or phone keys, the reader can be upgraded, or you can start with the Wireless Online + Openow SNZR3KUSSB. See the SMARTair System Information Guide for how the tiers compare.
How the SMARTair Standalone Reader is Used
In Standalone mode the reader stores user credentials and PIN codes itself. When a valid credential or PIN is presented, it switches its relay output to unlock the connected door or access control device.
- Install the reader on the wall near the door or gate, with the relay board on the secure side.
- Connect relay 1 on the relay board to the electric strike, electromagnetic lock or door automation controller.
- Program the authorised PIN codes and RFID credentials using SMARTair programming cards.
- Users gain access by presenting a credential, entering a PIN, or both, depending on how the reader is set up.
Standalone readers suit locations that need a simple, reliable electronic access solution without connecting to a centralised access control network.
Full Specifications
The MURAL reader, relay board, power, environmental and certification data is shared across the MURAL wall reader range and comes from the wall reader datasheet, which documents the version without a keypad; the keypad and PIN details are specific to this keypad version.
Related SMARTair Products and Guides
- Other SMARTair wall readers. For real-time control and Openow smartphone access, step up to the Wireless Wall Reader with Keypad. If a keypad is not required, the MIFARE i-Reader R4N range covers Slim and Wide formats across the Update-on-Card, Wireless Online and Openow tiers - for example the Slim Update-on-Card S4BR2Slim2 and Wide base S4BR2Wide2.
- Other SMARTair formats. For door-mounted electronic hardware use a SMARTair i-max Standalone escutcheon or Standalone knob cylinder; for gates and padlockable points, the SMARTair i-gate padlock SNBBP3XI runs on Update-on-Card + Openow rather than Standalone. The full list of devices for the same site is under System Integration.
- Commissioning. The reader is set up with SMARTair programming cards and serviced through its jack with the SMARTair portable programmer. When the site moves to Update-on-Card, credentials are written with the SMARTair USB encoder, and Openow is enabled with an Openow mobile access licence.
- Selecting and specifying. Compare access methods and management tiers in our access methods chapter and gateway comparison chapter, check door and opening suitability with the door type guide, and read about mobile keys in our app platforms chapter. Also useful: Australian standards, installation and troubleshooting, site survey and installation, the realities of electronic door locks, and the Smart Lock Buyer's Guide.
Frequently Asked Questions
An electric strike, electromagnetic lock or escape-route device for relay 1 to command, a 12-24 VAC/VDC power supply and cabling to the relay board - plus SMARTair programming cards to set it up. See What's Included.
Yes - users open with a code, an HID iCLASS credential or a combination of both, depending on how the reader is set up.
No. In Standalone mode the reader holds its own users and permissions and is set up with programming cards (Product Overview). If you later want central management, it can be upgraded to Update-on-Card and then Wireless Online (wall reader datasheet); adding Openow also brings in TS1000 and the Openow mobile access licence.
Not as listed. Openow can be added by fitting the Openow Bluetooth 4.2 module and a firmware upgrade, with the site then managed in TS1000 with the Openow mobile access licence - or choose the Wireless Online + Openow SNZR3KUSSB, which has Openow built in.
Additional Information
- Dispatch and planning. This reader usually ships in 3 business days. Order the rest of the job at the same time - the strike or lock, the power supply, programming cards and credentials - so it can be commissioned in one visit.
- Plan the power and cabling. The reader runs from a 12-24 VAC/VDC supply through its relay board, and the relay switches the lock without powering it, so the strike or magnetic lock needs its own supply. Choose a fail-safe or fail-secure locking device to suit the opening. It is a job for an experienced access control installer - see advice and installation.
- Keep the programming cards safe. A Standalone reader is set up and changed with SMARTair programming cards, and lost cards are cancelled by hand on this tier (feature comparison) - store the cards securely and record who holds which credential.
- Match the credential first. This listing reads HID iCLASS; the MIFARE equivalents are the i-Reader R4N readers. If the site already has cards, send us a sample before ordering.
- Data and support. On Standalone, users, PINs and events are held in the reader itself. When the site moves to a managed tier, TS1000 keeps the site database on your own server (Product Overview). For where access platforms keep data, see platforms hosted outside China.
Warranty
ASSA ABLOY branded products purchased new in Australia from authorised resellers are covered against defects in materials and workmanship for:
- Mechanical components: 10 years
- Electrical and electronic components: 5 years (excluding batteries)
- Cylinders and keys: 3 years
Download PDF Resources
ASSA ABLOY's technical information for the SMARTair MURAL wall reader in its version without a keypad - the technical data, reader module and control unit, operating modes, the two-relay board and the dimension drawing it shares with this keypad reader.
The May 2023 technical overview - the four management systems and the equipment each needs, the feature comparison, system architecture, TS1000 and Web Manager, credentials, and the wall reader in the other-devices table on page 10.
The May 2022 benefits guide - the management levels with decision guidance on page 4 (Pro Wireless Online with the hub coverage note, Openow and Update-on-Card), Openow virtual keys and the wall reader device page.
SMARTair Standalone Wall Reader (SNAR3KUSSB) - FAQ, Set-Up and Owner's Guide
Everything below is here to help you choose, install and run this reader. For general smart lock questions see our Smart Lock FAQ (Chapter 13), and for the wider picture start with the Buyer's Guide.
Choosing This Reader
It is SMARTair's Standalone wall reader with a PIN keypad and an HID iCLASS card reader. It holds its own users and permissions, needs no network, and releases an electric strike, magnetic lock or door operator through its relay board.
By management tier. The SNAR3KUSSB is Standalone - no network, set up with programming cards - and the SNZR3KUSSB is Wireless Online + Openow, managed centrally in TS1000 through SMARTair hubs. Both read HID iCLASS and have a keypad. See the wall reader comparison.
A keypad wall reader if you want PIN entry or card + PIN, and your site runs HID iCLASS. The i-Reader R4N readers - for example the S4ZR2DSlim or S4ZR2PWide - have no keypad and read MIFARE, in Slim and Wide formats.
No. It checks the credential and switches a relay; the lock is a separate electric strike, electromagnetic lock, escape-route device or door operator wired to the relay board (wall reader datasheet). On a door without electric locking, a battery-powered SMARTair i-max Standalone escutcheon or Standalone knob cylinder locks the door by itself.
The SNZR3KUSSB is the Wireless Online + Openow version. It costs more, and in return changes and events travel in real time through SMARTair hubs, and Openow phone keys are enabled.
Cards, Tags and Credentials
HID iCLASS 13.56 MHz cards and fobs, added at the reader with SMARTair programming cards on Standalone. The MURAL reader range also lists MIFARE Classic and Ultralight, SKIDATA and DESFire; this listing is the iCLASS version. Browse RFID cards, fobs and tags.
Only if they are HID iCLASS. An existing card of the right type can often carry SMARTair data too, because SMARTair uses the credential's free memory alongside other services (Product Overview) - send us a sample card and we will check it.
2-4 cm for standard RFID credentials (wall reader datasheet). See how RFID credentials work.
On a Standalone site the card is cancelled by hand - automatic cancellation of lost cards is a feature of the managed tiers, not Standalone (feature comparison). Keep a record of who holds which credential.
Yes - the reader holds 30 time zones with five periods each, and state tables can change its operating mode up to 20 times a day. Activation and expiry dates on credentials come with the managed tiers, not Standalone (feature comparison).
Yes - users open with a code, an HID iCLASS credential or a combination of both, depending on how the reader is set up. See PIN access explained.
Openow Phone Keys
ASSA ABLOY's mobile credential: a virtual key in the Openow app, used over Bluetooth. Keys are sent, revoked and updated over the air, are end-to-end encrypted, and a cancelled key vanishes from the phone (Information Guide).
Yes - by fitting the Openow Bluetooth 4.2 module and a firmware upgrade. Openow keys are issued from TS1000 with the Openow mobile access licence, so the site moves from programming-card set-up to TS1000 management. If phone keys are a must from day one, the Wireless Online + Openow SNZR3KUSSB has Openow built in.
The Openow mobile access licence enabled in TS1000, users with the Openow app on their phones, and TS1000's cloud connection, which carries keys to phones over HTTPS 443 (system architecture).
They open the Openow app, press the padlock and hold the phone to the reader. Green means opened, orange means the phone could not connect (try again) and red means no access - no rights, a blocked door or outside the time schedule (Openow User Guide; February 2019, so screens may differ from today's app).
Standalone Set-Up and Upgrades
With SMARTair programming cards - the Standalone tier needs only the door devices and a programming card, with no software licence, encoder or hubs (Product Overview).
We list the SMARTair Standalone Programming Card - iCLASS. Ask us if your site already has Standalone programming cards.
Yes. SMARTair wall readers can be upgraded from Standalone to Update-on-Card and then Wireless Online by adding an RF module and a firmware upgrade; the R4 circuit is required (wall reader datasheet).
Once a year, with the portable programmer; daylight saving changes are automatic, and the clock and calendar are held for 48 hours without power by an internal backup battery (wall reader datasheet).
Emergency opening and service - it takes the portable programmer and the emergency kit (wall reader datasheet).
Wiring, Power and Installation
A 12-24 VAC/VDC supply, connected through the relay board. Maximum consumption for the reader and relay board together is 500 mA at 12 V or 250 mA at 24 V (wall reader datasheet). The power supply is not included.
Relay 1 commands the electromechanical lock, which is not included, and relay 2 can be used for other purposes - its function is set on the board's dip switch, or in the management software on a managed site (wall reader datasheet). A smaller single-relay board and an 8-output lift board are available as spare parts.
It depends on the opening. A fail-safe lock releases when power is lost and a fail-secure lock stays locked, so the choice follows the opening's exit and security needs. We will help you pick the strike or magnetic lock when we quote.
Yes. The relay board has inputs for a door position sensor - so intrusion or a door left open is reported - and a request-to-exit push button, plus a tamper switch in the board itself. The sensor and button are not included (wall reader datasheet).
On the secure side of the opening, away from the weather - the IP55 rating covers the wall reader. It comes in a box for surface mounting, and the board can also go on a DIN rail (enclosure not included; the tamper switch must then be overridden or added separately) (wall reader datasheet).
The reader-to-relay-board communication is encrypted, so no manipulation of the wiring between the two can open the door (wall reader datasheet).
The reader and relay board stop until power returns, while users and events stay in non-volatile memory and the clock is held for 48 hours by an internal backup battery (wall reader datasheet). What the door does depends on the lock - see what actually happens in a power outage.
An experienced access control installer - it is a wired job with a power supply, a relay board and an electric lock to set up, and the reader then has to be initialised and commissioned in SMARTair. See when DIY makes sense, our advice and installation and professional installation.
Operating Modes and Settings
Standard; Standard ADA (standard operation with double opening time, for accessible doors); Passage (always open, set by time zone or by an authorised user after double badging); Double user (two valid credentials needed); and First user (standard until the first valid user enters, then passage until closed by an authorised user or a time zone) (wall reader datasheet).
In standard mode the opening time is configurable from 4 to 10 seconds, and the ADA mode doubles it (wall reader datasheet).
The green and red LED and the buzzer signal access authorised or denied (wall reader datasheet).
Yes - state tables can change the operating mode up to 20 times per door per day, for example passage mode during business hours (wall reader datasheet).
Outdoor Use and Environment
The wall reader is IP55 rated, for -20 to +80 degrees C and up to 85 percent humidity; the relay board is rated -10 to +80 degrees C and belongs on the secure side (wall reader datasheet). See IP ratings explained.
The IP rating covers water and dust, not salt air, and ASSA ABLOY doesn't quote a salt spray figure for the reader. Its warranty excludes corrosion, so on the coast choose a sheltered position and check the reader regularly - see coastal environments and what coastal Queensland does to locks.
Software and System Management
No - it is set up with programming cards (Product Overview). TS1000 and Web Manager come in when the site moves to Update-on-Card or Wireless Online (software).
Yes. SMARTair management systems can be combined on one site (system architecture), so a building can run different tiers where they suit. On a Standalone site the reader sits alongside the SMARTair Standalone knob cylinders (SNAB43X030E10MI black, SNAW43X030E10MI white) and i-max Standalone escutcheons (SNAB43SL2V648DI, SNAB43SL2V908DI, SNAB47SL2V648DI, SNAB47SL2V908DI) - all HID iCLASS, so the same cards open every door, and all are set up with programming cards.
1,500 users and 600 events in normal mode, or unlimited users filtered into 48 groups with 1,000 events on a high-traffic door (wall reader datasheet).
Yes - the control unit has upgradeable firmware (wall reader datasheet).
On Standalone, users, PINs and events are held in the reader itself; if the site moves to a managed tier, TS1000 keeps the site database on your own server (Product Overview). For how access platforms compare on data hosting, see platforms hosted outside China and security and data sovereignty.
Compliance, Warranty and Ordering
CE (EMC, R&TTE), RoHS, REACH, WEEE, RCM and R-NZ (wall reader datasheet). See Chapter 11 for what RCM means in Australia.
ASSA ABLOY's Australian warranty - 10 years on mechanical components and 5 years on electrical and electronic components, batteries excluded. The full terms are in the Warranty section.
This reader usually ships in 3 business days. Order the lock, power supply and programming cards at the same time so the opening can be commissioned in one visit.
Related Products, Guides and Chapters
The other keypad wall reader: SNZR3KUSSB (Wireless Online + Openow keypad reader)
The MIFARE i-Reader R4N range: S4BR2Slim2 (i-Reader Slim, Update-on-Card) · S4BR2Slim1 (i-Reader Slim, Update-on-Card + Openow) · S4BR2Slim3 (i-Reader Slim, Wireless Online) · S4ZR2DSlim (i-Reader Slim, Wireless Online + Openow) · S4BR2Wide2 (i-Reader Wide, base) · S4BR2Wide1 (i-Reader Wide, Update-on-Card + Openow) · S4ZR2PWide (i-Reader Wide, Wireless Online + Openow)
Devices for the same site: SNAB43X030E10MI · SNAW43X030E10MI · SNAB43SL2V648DI · SNAB43SL2V908DI · SNAB47SL2V648DI · SNAB47SL2V908DI
System components: Encoder - USB RFID Credential Programmer STCED3 · Portable Programmer STCPCC · Standalone Programming Card - iCLASS SNACLICSTAIC · Mobile Access Licence - Openow SNCCLICMOBILE
Categories: Fob / Card / RFID · RFID / Fobs / Tags / Cards · PIN Code
Buyer's Guide chapters: Ch 03 Access Methods · Ch 04 Door Types · Ch 08 Gateways · Ch 09 Accessibility · Ch 10 Brand Profiles · Ch 11 Standards and IP Ratings · Ch 12 Troubleshooting · Ch 13 FAQ · Ch 15 App Platforms
Helpful blog reading: Power Outages and Electronic Locks · The Realities of Electronic Door Locks · How Long Do Digital Door Locks Last? · Which Platform for Commercial Sites? · Your Data and China · Site Survey and Installation
What's in the Box - SNAR3KUSSB
- SMARTair MURAL wall reader with keypad - HID iCLASS card reader and PIN keypad, black
- SMARTair relay board in its surface-mount box - two output relays, inputs for door position and request to exit, and a tamper switch in the board
- Installation mounting hardware
- Setup and programming documentation
PDF Files - SNAR3KUSSB
ASSA ABLOY's technical information for the SMARTair MURAL wall reader in its version without a keypad - the technical data, reader module and control unit, operating modes, the two-relay board and the dimension drawing it shares with this keypad reader.
The May 2023 technical overview - the four management systems and the equipment each needs, the feature comparison, system architecture, TS1000 and Web Manager, credentials, and the wall reader in the other-devices table on page 10.
The May 2022 benefits guide - the management levels with decision guidance on page 4 (Pro Wireless Online with the hub coverage note, Openow and Update-on-Card), Openow virtual keys and the wall reader device page.
ASSA ABLOY Warranty Overview
ASSA ABLOY branded products sold in Australia are covered by manufacturer warranties issued by ASSA ABLOY Australia Pty Ltd. Warranty coverage varies depending on mechanical components, electronic components, cylinders and finish categories.
This overview summarises the structure of ASSA ABLOY warranty coverage. Full terms, exclusions and claim procedures are set out in the official ASSA ABLOY Warranty document.
Warranty Periods Summary
Finish & Material Notes
- Stainless steel does not mean stain-free. Tea staining is not covered where cleaning and maintenance guidelines have not been followed.
- Cosmetic, decorative and appearance damage is not covered.
- Battery failure or battery leakage damage is not covered.
What the Warranty Covers
- Defects in material and workmanship within the applicable period.
- Assessment by ASSA ABLOY to determine repair, replacement with the same or closest equivalent product, or refund of purchase price.
- Remedy determined at ASSA ABLOY’s discretion.
Common Exclusions
- Normal wear and tear.
- Misuse, abuse or installation outside published technical specifications.
- Improper maintenance or neglect.
- Unauthorised modification or repair.
- Use of non-genuine ASSA ABLOY parts or substitute components.
- Exposure to corrosive environments including coastal air, salt spray, chemicals, contamination or high humidity.
- Removal, refitment, freight or labour charges.
- Second-hand or imported products not sold through authorised Australian channels.
Warranty Claim Process
- Retain proof of original purchase.
- Return the product to the original authorised retailer where applicable.
- If claiming directly, obtain a case number before returning goods.
- Securely package returned goods and clearly reference the case number.
- Warranty assessment determines repair, replacement or refund.
Australian Consumer Law
ASSA ABLOY warranties operate in addition to rights available under the Australian Consumer Law. Goods come with guarantees that cannot be excluded. Customers may be entitled to a replacement or refund for a major failure and compensation for reasonably foreseeable loss or damage.
Where a product fails to meet acceptable quality standards and the failure does not amount to a major failure, the customer is entitled to repair or replacement.
Official Warranty Documents
Confused? Overwhelmed? We get it.
Choosing the right smart lock can be genuinely tricky - door types, backsets, app platforms, compatibility with your existing hardware... there is a lot to consider. We have decades of experience fitting locks of all types, including smart locks, and we are happy to help.
Our expert recommendation service is free. Upload a few photos of your door and describe what you need, and one of our qualified locksmiths will give you a personalised recommendation.
Get Your Free Recommendation →How it works - three easy steps:
1. Upload photos
A few clear shots of your door, lock and frame - inside and out.
2. We assess
Our locksmith reviews your setup and requirements - door type, weather exposure, how you want to use it.
3. You get a recommendation
A personalised recommendation tailored to your door, budget and needs. No pressure, no upsell.
Also useful while you are deciding: